General information
You can connect the OASYS
PCI to an ADAT-compatible digital mixer in various ways,
depending on your other equipment and your personal
preference.
Top
of Page
Mixer as word clock
master
The simplest way is to use
the mixer as the word clock master. In this case:
1. Connect both the OASYS
PCI's ADAT optical input and output to the mixer.
2. Make sure that the
mixer is set to use its internal clock.
3. Set the OASYS PCI's
word clock source to ADAT.
Top
of Page
OASYS PCI as word clock
master
In some cases, you may
wish to use the OASYS PCI as the master clock. In this
case:
1. Connect the OASYS PCI's
ADAT optical input and output to the mixer.
2. Set the OASYS PCI's
word clock source to Internal.
3. Set the mixer to use
the OASYS PCI's ADAT output as the master clock.
Top
of Page
External word clock
generator as master
You may also wish to use a
stand-alone word clock generator or SMPTE-to-digital audio
converter as the master. In this case:
1. Connect the word clock
generator's output to the word clock inputs of both the
mixer and the OASYS PCI.
2. Set the word clock
source of both devices to Word Clock.
Top
of Page
Yamaha 02R
The OASYS PCI and the
Yamaha 02R digital mixer can be connected in many different
ways, depending on the rest of your studio setup. Either the
OASYS PCI or the 02R can be the word clock master, each
using either the ADAT optical cables or a dedicated word
clock cable.
Whatever configuration you
decide upon, you'll need to set all the word clocks
accordingly. One possible setup is to sync the 02R to the
OASYS PCI, using the OASYS PCI's ADAT output. In this
case:
1. Connect the OASYS PCI's
optical input and output to an ADAT I/O card on the
02R.
2. On the 02R, Press the
Digital I/O button.
3. Go to the Word Clock
Select page.
This page shows a list of
all the installed I/O cards, and allows you to select a pair
of channels from any card as the master clock source. You
can also select the dedicated word clock input, or the
internal clock.
4. Set the 02R to use the
ADAT 1/2 channels from the card connected to the OASYS
PCI.
5. In the digital audio
program, set the OASYS PCI's word clock source to
Internal.
Top